Why did the customer contact us?

the customer would like an estimate on insulation for the attic as well as the basement.

Solutions provided:

Existing insulation is approximately R19. Needs to have additional blown in to bring up to current code recommendations, R49.

Blow in additional R30 cellulose in the attic. Apply plastic drop cloths to closet space to protect the environment. Provide negative airflow to keep dust out of the living area.

Install baffles as needed throughout both attics.

Basement is not an issue at this time. May need to add about 28 LF of spray foam to outer rim joist in the utility room.

Install 2 x 2 insulated attic hatch cover.

Insulate rear garage attic, same as the main attic with blown cellulose.